Control Transformer Single Phase Tape Insulated

Control Transformers

Control transformers are built to serve electronic circuits that need constant voltage and current at low power and volt amp rating. Control transformers are best suited for industrial environments where electromagnetic devices like solenoids and relays are being deployed. These transformers can regulate output voltage and inrush capability in electromagnetic devices. Current transformers have very high quality insulation across all its winding. A control transformer, typically employed in electronic circuits demanding consistent voltage at a low power or volt-amp rating, serves as an isolation transformer. Control Transformers are specifically designed to convert high-voltage power supply to a lower voltage level suitable for control circuits.

Single Phase Tape Insulated / Resin Cast Control / Voltage Transformer

Unique Features

  • Analog load bar graph for indicating average current in %
  • Compact depth (54mm)

Standard Features

  • 96 mm × 96 mm DIN quadratic
  • Single line 6 digit LED display
  • True RMS measurement up to 15th harmonic
  • Energy pulse LED on front panel : 1000 imp / kWh (Meter Constant)
  • Onsite programmable :
  • Indication for healthy phases
  • Indication for reverse (Irev)
  • Screw type i/p current termination

Parameters

  • Active energy (kWh)
  • Old active energy (kWh)
  • Energy billing in specified currency

Technical Specification

  • Input Voltage: 10 -290V L-N (500VLL)
  • Frequency: 45 to 65 Hz
  • Current: 1A or 5A
  • AUX Supply: 230 VAC. ± 20%
  • Accuracy: Class 1.0,Optional: Class 0.5
  • Operating Temperature range: 0 to +50degC
  • Enclosure: Front- IP54 (Dust & water) Back – IP20 Material – Polycarbonate (UL94 VO)
  • High voltage test: 2.2 kVAC 50Hz for 1 minute between all electrical Circuits

Three Phase Tape Insulated / Resin Cast Control / Voltage Transformer

Unique Features

  • Protection against accidental opening of secondary terminals of external C.T
  • Analog load bar graph for indicating average current in %
  • Communication LED for MODBUS (RS – 485) on front panel
  • Compact depth even with optional features (61mm)

Standard Features 

  • 96 mm × 96 mm DIN quadratic
  • Single line 8 digit LED display
  • True RMS measurement up to 15th harmonic
  • Energy pulse LED on front panel : 3600 imp / kWH (Meter Constant)
  • Onsite programmable : 3 phase 4 wire / 3 wire / 2 wire, CT / PT primary, CT secondary 1A or 5A, PT secondary (100 VLL to 500 VLL).
  • Indication for healthy phases (Von)
  • Indication for reverse (Irev)

Optional Features

  • MODBUS (RS – 485)
  • 1 relay output (As pulse output)

Parameters for Ace 3E1 through display

  • Active energy (kWh)
  • Old active energy (kWh)
  • Energy billing in specified currency

Parameters for Ace 3E1 through MODBUS (RS – 485)

  • Basic : V,I, Hz
  • Power : kW, kVAr, kVA, PF, Ø
  • Energy : kWh, kVAh, Old kWh
  • Energy billing in specified currency

Technical Specification

  • Input Voltage : 10 -290V L-N (500VLL)
  • Frequency : 45 to 65 Hz
  • Current: 1A or 5A
  • AUX Supply : 80 – 300V AC/DC
  • Accuracy : Class 1.0,Optional: Class 0.5
  • Operating Temperature range : 0 to +50degC
  • Applicable Standards : IEC 61010, IEC 60529, IEC 61326
  • Enclosure : Front- IP54 (Dust & water)
  • Back – IP20 Material – Polycarbonate (UL94 VO)
  • Installation Categary : III
  • Pollution Degree : 2
  • High voltage test : 3.3 kVAC 50Hz for 1 minute between all electrical Circuits (2.2 kVAC for Mobbus & Relay)

Single Phase Tape Insulated / Resin Cast Control / Voltage Transformer

Technical Data

Control Transformers - Newtek

Three Phase Tape Insulated / Resin Cast Control / Voltage Transformer.

Technical Data

Single Phase Tape Insulated / Resin Cast Control / Voltage Transformer

Technical Data

Control Transformers - Newtek

Industries

Enquiry