MFM Meter
Digital meters is a measuring device based on microcontroller. It measures a number of power parameters and while communicating with a remote server. As India transitions from conventional to smart grid, Newtek provides future-ready digital meters that make power measurement precise, accurate and easy to follow. Efficient digital meters make it easier for businesses to calculate power consumption on hourly and daily bases, and make adjustments accordingly to save power costs.
MFM Meter Ace 353
Parameters
- Basic : V, I, Hz
- Power : kW, PF
- System : RPM, Run – hour
Optional Features
- MODBUS (RS – 485)
- Relay output (As limit switch)
MFM Meter Ace 355
Parameters
- Basic : V, I, Hz
- Power : kW, PF
- Energy : kWh
- System : RPM, Run – hour
- Unbalance in % : V, I
- Event Counter : Event Counter Run – hour
Optional Features
- MODBUS (RS – 485)
- 1 Relay output (As pulse or limit switch)
MFM Meter Ace 354
Parameters
- Basic : V, I, Hz
- Power : kW, PF
- Energy : kWh
- System : RPM, Run – hour
- Unbalance in % : V, I
- Event Counter : Event Counter Run – hour
Optional Features
- MODBUS (RS – 485)
- 1 Relay output (As pulse or limit switch)
MFM Meter Ace 357
Parameters
- Basic : V, I, Hz
- Power : kW, kVAr, kVA, PF, Ø, In
- Demarnd : I, kW, kVA
- Energy : kWH, kVArh, kVAh
- System : RPM, Run – hour, On – hour, Interruptions
- Unbalance in % : V, I
- Net energy : (kWh)
Optional Features
MFM Meter Ace 357T
Parameters
- Basic : V, I, Hz
- Power : kW, kVAr, kVA, PF, Ø, In
- Demarnd : I, kW, kVA
- Energy : kWH, kVArh, kVAh
- Power quality parameters :
- THD in % : V, I
- Harmonic Voltage : Total fundamental distorted
- Harmonic Current : Total fundamental distorted
- Total demand distortion in % K – factor (Harmonic factor) : Total fundamental distorted
- System : RPM, Run – hour, On – hour, Interruptions
- Unbalance in % : V, I
Optional Features
MFM Meter Ace 357TH
Parameters
- Basic : V, I, Hz
- Power : kW, kVAr, kVA, PF, Ø, In
- Demarnd : I, kW, kVA
- Energy : kWH, kVArh, kVAh
- Power quality parameters :
- THD in % : V, I
- Harmonic Voltage : Total fundamental distorted
- Harmonic Current : Total fundamental distorted
- Total demand distortion in % : K – factor (Harmonic factor) Individual odd harmonics (3rd, 5th…15th) in %
- System : RPM, Run – hour, On – hour, Interruptions
- Unbalance in % : V, I
Optional Features
MFM Meter Ace 357C
Parameters
- Screw type connectors
- Input current connections of Ace 357C : Screw type connectors are available on Ace 357C for input current terminations
Optional Features
MFM Meter Ace 357D
Parameters
- Direct measurement of current up to 30A AC
- Max value for direct current measurement programmable on site from 5A to 30A
Optional Features