Energy Meter
Digital meters is a measuring device based on microcontroller. It measures a number of power parameters and while communicating with a remote server. As India transitions from conventional to smart grid, Newtek provides future-ready digital meters that make power measurement precise, accurate and easy to follow. Efficient digital meters make it easier for businesses to calculate power consumption on hourly and daily bases, and make adjustments accordingly to save power costs.
Energy Meter Neo EM3
Unique Features
- Analog load bar graph for indicating average current in %
- Compact depth (54mm)
Standard Features
- 96 mm × 96 mm DIN quadratic
- Single line 6 digit LED display
- True RMS measurement up to 15th harmonic
- Energy pulse LED on front panel : 1000 imp / kWh (Meter Constant)
- Onsite programmable :
- Indication for healthy phases
- Indication for reverse (Irev)
- Screw type i/p current termination
Parameters
- Active energy (kWh)
- Old active energy (kWh)
- Energy billing in specified currency
Technical Specification
- Input Voltage: 10 -290V L-N (500VLL)
- Frequency: 45 to 65 Hz
- Current: 1A or 5A
- AUX Supply: 230 VAC. ± 20%
- Accuracy: Class 1.0,Optional: Class 0.5
- Operating Temperature range: 0 to +50degC
- Enclosure: Front- IP54 (Dust & water) Back – IP20 Material – Polycarbonate (UL94 VO)
- High voltage test: 2.2 kVAC 50Hz for 1 minute between all electrical Circuits
Energy Meter Ace 3E1
Unique Features
- Protection against accidental opening of secondary terminals of external C.T
- Analog load bar graph for indicating average current in %
- Communication LED for MODBUS (RS – 485) on front panel
- Compact depth even with optional features (61mm)
Standard Features
- 96 mm × 96 mm DIN quadratic
- Single line 8 digit LED display
- True RMS measurement up to 15th harmonic
- Energy pulse LED on front panel : 3600 imp / kWH (Meter Constant)
- Onsite programmable : 3 phase 4 wire / 3 wire / 2 wire, CT / PT primary, CT secondary 1A or 5A, PT secondary (100 VLL to 500 VLL).
- Indication for healthy phases (Von)
- Indication for reverse (Irev)
Optional Features
- MODBUS (RS – 485)
- 1 relay output (As pulse output)
Parameters for Ace 3E1 through display
- Active energy (kWh)
- Old active energy (kWh)
- Energy billing in specified currency
Parameters for Ace 3E1 through MODBUS (RS – 485)
- Basic : V,I, Hz
- Power : kW, kVAr, kVA, PF, Ø
- Energy : kWh, kVAh, Old kWh
- Energy billing in specified currency
Technical Specification
- Input Voltage : 10 -290V L-N (500VLL)
- Frequency : 45 to 65 Hz
- Current: 1A or 5A
- AUX Supply : 80 – 300V AC/DC
- Accuracy : Class 1.0,Optional: Class 0.5
- Operating Temperature range : 0 to +50degC
- Applicable Standards : IEC 61010, IEC 60529, IEC 61326
- Enclosure : Front- IP54 (Dust & water)
- Back – IP20 Material – Polycarbonate (UL94 VO)
- Installation Categary : III
- Pollution Degree : 2
- High voltage test : 3.3 kVAC 50Hz for 1 minute between all electrical Circuits (2.2 kVAC for Mobbus & Relay)