VAF Power Meters
Digital meters is a measuring device based on microcontroller. It measures a number of power parameters and while communicating with a remote server. As India transitions from conventional to smart grid, Newtek provides future-ready digital meters that make power measurement precise, accurate and easy to follow. Efficient digital meters make it easier for businesses to calculate power consumption on hourly and daily bases, and make adjustments accordingly to save power costs.
VAF Power Meter Neo 322
Standard Features
- 96 mm × 96 mm DIN quadratic
- 3 Line : 3 Digit LED display
- Onsite Programmable : 3 phase 4 wire/3 wire /2 wire. CT / PT Primary. CT Secondary 1A or 5A. PT Secondary (1OOVLL to 500VLL)
- Compact depth (54mm)
- Screw type i/p current termination
Parameters
- Basic : V, I, Hz
- System : RPM, Run-hour
- Unbclcnce in % : V, I
Technical Specification
- Input Voltage : 10 -290V L-N (500VLL)
- Frequency : 45 to 65 Hz
- Current : 1A or 5A
- AUX Supply : 230 VAC. ± 20%
- Accuracy : Class 1.0,Optional: Class 0.5
- Operating Temperature range : 0 to +50degC
- Enclosure : Front– IP54 (Dust & water) Back – IP20 Material – Polycarbonate (UL94 VO)
- High voltage test : 2.2 kVAC 50Hz for 1 minute between all electrical Circuits
VAF Power Meter Neo 323
Unique Features
- Pass through CT : Protection against accidental opening of secondary terminals of external C.T.
- Compact depth even with optional features (61mm)
- Optional Features : Up to 2 Relay outputs (AS Limit switch).
Standard Features
- 96 mm × 96 mm DIN quadratic
- 3 line – 4 digit LED display
- True RMS measurement up to 15th harmonic
- Onsite Programmable : 3 phase 4 wire / 3 wire / 2 wire, CT / PT Primary, CT Secondary 1A or 5A, PT Secondary (100VLL to 500VLL)
Parameters
- Basic : V, i, hZ
- System : RPM, Run – hour, On- hour, interruptions
Technical Specification
- Input Voltage: 10 -290V L-N (500VLL)
- Frequency: 45 to 65 Hz
- Current : 1A or 5A
- AUX Supply : 230 VAC. ± 20%
- Accuracy : Class 1.0,Optional: Class 0.5
- Operating Temperature range : 0 to +50degC
- Enclosure : Front- IP54 (Dust & water) Back – IP20 Material – Polycarbonate (UL94 VO)
- High voltage test : 2.2 kVAC 50Hz for 1 minute between all
electrical Circuits
VAF Meter Neo 323C
Standard Features
- 96 mm × 96 mm DIN quadratic
- 3 Line : 3 Digit LED display
- Onsite Programmable : 3 phase 4 wire/3 wire /2 wire. CT / PT Primary. CT Secondary 1A or 5A. PT Secondary (1OOVLL to 500VLL)
- Compact depth (54mm)
- Screw type i/p current termination
Parameters
- Basic : V, I, Hz
- System : RPM, Run-hour
- Unbclcnce in % : V, I
Technical Specification
- Input Voltage : 10 -290V L-N (500VLL)
- Frequency : 45 to 65 Hz
- Current : 1A or 5A
- AUX Supply : 230 VAC. ± 20%
- Accuracy : Class 1.0,Optional: Class 0.5
- Operating Temperature range : 0 to +50degC
- Enclosure : Front– IP54 (Dust & water) Back – IP20 Material – Polycarbonate (UL94 VO)
- High voltage test : 2.2 kVAC 50Hz for 1 minute between all electrical Circuits