Multifunction Meter

MFM Meter

Digital meters is a measuring device based on microcontroller. It measures a number of power parameters and while communicating with a remote server. As India transitions from conventional to smart grid, Newtek provides future-ready digital meters that make power measurement precise, accurate and easy to follow. Efficient digital meters make it easier for businesses to calculate power consumption on hourly and daily bases, and make adjustments accordingly to save power costs.

MFM Meter Ace 353

Parameters

  • Basic : V, I, Hz
  • Power : kW, PF
  • System : RPM, Run – hour

Optional Features

  • MODBUS (RS – 485)
  • Relay output (As limit switch)

MFM Meter Ace 355

Parameters

  • Basic : V, I, Hz
  • Power : kW, PF
  • Energy : kWh
  • System : RPM, Run – hour
  • Unbalance in % : V, I
  • Event Counter : Event Counter Run – hour

Optional Features

  • MODBUS (RS – 485)
  • 1 Relay output (As pulse or limit switch)

MFM Meter Ace 354

Parameters

  • Basic : V, I, Hz
  • Power : kW, PF
  • Energy : kWh
  • System : RPM, Run – hour
  • Unbalance in % : V, I
  • Event Counter : Event Counter Run – hour

Optional Features

  • MODBUS (RS – 485)
  • 1 Relay output (As pulse or limit switch)

MFM Meter Ace 357

Parameters

  • Basic : V, I, Hz
  • Power : kW, kVAr, kVA, PF, Ø, In
  • Demarnd : I, kW, kVA
  • Energy : kWH, kVArh, kVAh
  • System : RPM, Run – hour, On – hour, Interruptions
  • Unbalance in % : V, I
  • Net energy : (kWh)

Optional Features

MFM Meter Ace 357T

Parameters

  • Basic : V, I, Hz
  • Power : kW, kVAr, kVA, PF, Ø, In
  • Demarnd : I, kW, kVA
  • Energy : kWH, kVArh, kVAh
  • Power quality parameters :
  • THD in % : V, I
  • Harmonic Voltage : Total fundamental distorted
  • Harmonic Current : Total fundamental distorted
  • Total demand distortion in % K – factor (Harmonic factor) : Total fundamental distorted
  • System : RPM, Run – hour, On – hour, Interruptions
  • Unbalance in % : V, I

Optional Features

MFM Meter Ace 357TH

Parameters

  • Basic : V, I, Hz
  • Power : kW, kVAr, kVA, PF, Ø, In
  • Demarnd : I, kW, kVA
  • Energy : kWH, kVArh, kVAh
  • Power quality parameters :
  • THD in % : V, I
  • Harmonic Voltage : Total fundamental distorted
  • Harmonic Current : Total fundamental distorted
  • Total demand distortion in % : K – factor (Harmonic factor) Individual odd harmonics (3rd, 5th…15th) in %
  • System : RPM, Run – hour, On – hour, Interruptions
  • Unbalance in % : V, I

Optional Features

MFM Meter Ace 357C

Parameters

  • Screw type connectors
  • Input current connections of Ace 357C : Screw type connectors are available on Ace 357C for input current terminations

Optional Features

MFM Meter Ace 357D

Parameters

  • Direct measurement of current up to 30A AC
  • Max value for direct current measurement programmable on site from 5A to 30A

Optional Features

Industries