VAF Meter Neo 322

Project Image
  • 96 mm × 96 mm DIN quadratic
  • 3 Line : 3 Digit LED display
  • Onsite Programmable : 3 phase 4 wire/3 wire /2 wire. CT / PT Primary. CT Secondary 1A or 5A. PT Secondary (1OOVLL to 500VLL)
  • Compact depth (54mm)
  • Screw type i/p current termination
  • Basic : V, I, Hz
  • System : RPM, Run-hour
  • Unbclcnce in % : V, I

Input Voltage

10 -290V L-N (500VLL)

Frequency 

45 to 65 Hz 

Current 

1A or 5A 

AUX Supply

230 VAC. ± 20%  

Accuracy  Class 1.0,Optional: Class 0.5

Operating Temperature 

range 

0 to +50degC

Enclosure

Front- IP54 (Dust & water) 

Back - IP20  Material - Polycarbonate (UL94 VO)

High voltage test

2.2 kVAC 50Hz for 1 

minute between all 
electrical Circuits 

Request a Quote

VAF Meter Neo 323

Project Image
  • Pass through CT : Protection against accidental opening of secondary terminals of external C.T.
  • Compact depth even with optional features (61mm)
  • Optional Features : Up to 2 Relay outputs (AS Limit switch).
  • 96 mm × 96 mm DIN quadratic
  • 3 line - 4 digit LED display
  • True RMS measurement up to 15th harmonic
  • Onsite Programmable : 3 phase 4 wire / 3 wire / 2 wire, CT / PT Primary, CT Secondary 1A or 5A, PT Secondary (100VLL to 500VLL)
  • Basic : V, i, hZ
  • System : RPM, Run - hour, On- hour, interruptions

Input Voltage

10 -290V L-N (500VLL)

Frequency 

45 to 65 Hz 

Current 

1A or 5A 

AUX Supply

230 VAC. ± 20%  

Accuracy  Class 1.0,Optional: Class 0.5

Operating Temperature 

range 

0 to +50degC

Enclosure

Front- IP54 (Dust & water) 

Back - IP20  Material - Polycarbonate (UL94 VO)

High voltage test

2.2 kVAC 50Hz for 1 

minute between all 
electrical Circuits 

Request a Quote

VAF Meter Neo 323C

Project Image
  • Screw type connectors : Input current connections of Neo 323C for input current terminations.
  • Compact depth even with optional features (54mm)
  • All standard features of Neo 323 are applicable for NEO 323C
  • All technical specifications of NEO 323 are applicable for NEO 323C
  • Relay output (As limit switch).
  • Pass through CT : Protection against accidental opening of secondary terminals of external CT : reliable current connections.
  • Analog load bar graph for indicating average current in % : Shows frend of average load current in analog fashion
  • Energy pulse LED on front panel : Verification of energy accuracy
  • Communication LED for MODBUS (RS 485) on front panel : For Monitoring status of MODBUS communication
  • Compact depth even with optional features (61 mm) : Reduced panel size & hence cast saving
  • 96 mm × 96 mm DIN quadratic /3 line - 4 digit LED display
  • True RMS measurement up to 15th harmonic
  • Onsite programmable : 3 phase 4 wire / 3 wire / 2wire, CT / PT primary, CT secondary 1A or 5A, PT secondary (100VLL to 500VLL)

Input Voltage

10 -290V L-N (500VLL)

Frequency 

45 to 65 Hz 

Current 

1A or 5A 

AUX Supply

80 - 300V AC/DC

Accuracy Class 1.0,Optional: Class 0.5 

Operating Temperature 

range 

0 to +50degC

Applicable Standards IEC 61010, IEC 60529, IEC 61326

Enclosure

Front- IP54 (Dust & water) 

Back - IP20  Material - Polycarbonate (UL94 VO)

Installation Categary III
Pollution Degree 2

High voltage test

3.3 kVAC 50Hz for 1 

minute between all 
electrical Circuits  (2.2 kVAC for modbus & relay)

Request a Quote